PLAN REVIEW / PERMIT APPLICATION CHECKLIST

 

NORTH COVENTRY TOWNSHIP APPLICABLE CODES

Building Code              IBC   2009
Fire Code                      IFC   2009
Residential Code          IRC   2009
Electrical Code             NEC  2008    (NFPA-70)
Alarm Code                  NFPA 72   2007
Sprinkler Code             NFPA 13, 13D, 13R   2007

 

PERMIT APPLICATION FEES

See North Coventry Township Schedule of Fees

 

SUBMITTALS Two complete sets of plans, specifications & calculations.

TURNAROUND TIME--    Average  2-3 weeks  

MINIMUM PLAN REQUIREMENTS

Construction documents, plans and shop drawings submitted shall contain    
sufficient detail for evaluation of the protected hazards and the effectiveness
of the system. The shop drawings for the installation of fire protection
systems shall be submitted for review and approval prior to the installation
of the fire protection system.  

Plans shall be drawn to scale and shall identify by name, the designer and
the owner on every sheet.

The use, name and occupancy class of all rooms and spaces shall be
identified on all plans.

Mechanical, plumbing, electrical, fire sprinkler, and alarm details shall be
shown on the plans and represent the designs for those disciplines, along
with other information to show clearly the nature, character, and  location of
the proposed work.

 

ADDITIONAL ALARM PLAN REQUIREMENTS

Locations of ALL controls, alarm-initiating and notification appliances.

( NOTE: All ceiling mounted appliances shall be shown on reflective ceiling
plans which shall show locations of all HVAC duct grills and all luminaries.

Riser diagram

                    Alarm control and trouble signaling equipment.

                    Annunciation.

                    Power connection.

                    Mounting details.

                    Point to point wiring.

                    Detector spacing.

Door schedule.

                    Battery calculations   (24 hour standby) (5 min. sounding)   

                    Voltage drop calculations.

(NOTE: At a minimum the last device on all SLCs will be tested on final
inspection.) 

 

ADDITIONAL SPRINKLER PLAN REQUIREMENTS

                    Piping plans shall show ALL HVAC grillage, roof openings, and luminaries.
All zones shall be clearly marked.

                    Riser diagram labeling all components and indicating all supervisory
devices.

                    Contractor’s Material and Test Certificate for Aboveground Piping

                    Hanger details.

                    System water source(s) showing location, size and required backflow
prevention.  

                    In-rack sprinkler details

                    Air compressor schematic for dry pipe systems
Jockey pump schematic (if applicable)

                   System hydraulic analysis.

                   Water supply analysis.

            Underground water service should be inspected and “approved��� by the North
Coventry Township Water Authority prior to scheduling an inspection.

ALL FIRE ALARM SYSTEMS, AND SPRINKLERS SYSTEMS SHALL BE 100% TESTED BEFORE AN INSTALLATION INSPECTION CAN BE SCHEDULED. THE INSPECTION WILL NOT BE SCHEDULED UNTIL A “RECORD OF COMPLETEION��� IS RECEIVED.

 

To schedule inspections call 610-323-1694

 

Revised 1/13/2011

office hours/contact us

Kevin Hennessey
Township Manager (Email here)

Hours: Monday-Friday 8:30a-4:30p
Phone: 610-323-1694
Fax 610-323-7239


Submit your North Coventry Photo to <MyPhoto>

 

 

Information

Recycling in North Coventry
Our History
Directory
FAQ's
Voting Places
Open Record Policy
Taxes
Stormwater

Visions and Plans

Rt 100 Master Plan
Reconnections
Regional Comp
Resource Protection
NC Comprehensive


Codes

North Coventry General Code
Plan Review/Permit App Checklis
Zoning Map
Permit Fees
Applications

Community Links

North Coventry Wildlife Blog
North Coventry Elementary

Newsletter 2011

Fall 2011 Newsletter

Minutes

BOS January 3rd Minutes
BOS December 27th Minutes
BOS October 12th Minutes
BOS November 28th Minutes
BOS November 14th Minutes
BOS October 24th Minutes
BOS October 11th Minutes

Meeting Minutes Archives

links

Police Department
Norco Fire Company
North Coventry Food Pantry